THE GENERATION DIAGNOSTIC SYSTEM

A-50

HOW DOES IT WORK?

A-50 is an automatic immunoassay analyzer that measures the concentration of targeted analyte in body fluids such as blood, urine, and other samples. A-50 is designed for processing / analyzing large volumes of samples and can carry up to 80 tests per hour (depending on the type of item). In the case of blood samples, the A-50 removes the inconvenience of transferring the samples separately for testing because it collects sample from 3 ml blood tubes, which are commonly used worldwide, and provides automated testing results. The A-50 is suitable for medical institutions that need to process / analyze large volumes of samples, such as large / general hospitals and blood banks, and can efficiently manage test results with advanced storage capabilities and LIS / HIS connectivity.

STRUCTURE

MOVIE

ADVANTAGE

ADVANTAGE
Interface Expansion of user interface through adoption of Android OS
Display 10.1 "TFT electrostatic touch / keyboard and mouse connection
Data storage and update Available to store and search large amount of test results
- Patient test results (5,000), QC (1,000)
Data back-up and OS update using SD card
Optical technology Fluorescent optical module for high sensitive / semi-quantitative test available
Test mode Automated Test QC (Quality Control), Calibration and review (results saving) mode
Stability Reduced risk of test error based on the equation saving function
Connectivity Built-in printer, improved wired / wireless connectivity, LIS / HIS communication
USB hub chip supporting 4 USB ports
Convenience Keyboard adaptable for non-touchpad user
Improved convenience to input sample ID and tester ID

SPECIFICATIONS

ADVANTAGE
Dimensions 610 mm (L) x 610 mm (W) x 606 mm (H)
Weight 49 kg
Power supply AC 110-240 V, 47-63 Hz, 1.1-2.2 A
Data output 10.1” TFT touch colorLCD
Communication ports USB 4 ports, LAN port, RS-232
Temperature range for operation 15 ~ 35 °C
Temperature/humidity Temperature -20 ~ 50°C, Humidity Max. 70%
Data output LCD, built-in printer, RS-232 port
Test result storage Patient test results (5,000) / System check results (100)
Standard material (control) test results (5,000)
Save of ID chip information 500 ID chips (Max. 5 LOTs per each item)
Throughput Max. 80 tests per hour (different depending on item)

FAQ

  • QHow many tests per hour can be tested?

    A-50 is a fully automated immunoassay diagnostic device that can carry out up to 80 tests per hour.

  • QHow many items can I test at the same time?

    Two different items can be tested in bulk at the same time.